Power Drain Trap(pneumatic) Power Drain Trap(Electric) Reciprocating compressor(WRCT-08) Attachable Valve Strainer(WRST-SERIES) EXHAUST MUFFLER(ALWITCO, USA) DEWPOINT METER(Shawmeters.UK) Air Filter Element(WRE-SERIES)

Sensor+Motorized valve(WRET-1500,3000)

    ADVANTAGES

    ◎ Bigger size outlet valve (15A BALL VALVE)
    ◎ High reliable working
    ◎ Manual discharge is available
    ◎ No loss of compressed air
    ◎ Built-in counter to show working times
    ◎ Easy maintenance
    ◎ Visible working status
    ◎ There is contacts and alarm is installed in case of trouble.
    ◎ Higher capacity of condensed water
    ◎ A heater for antifreezing is available (OPTION)
    ◎ RS-485 communication is available. (OPTION)

    Operating & Feature

    openCondensed water is flowed into the trap through INLET and reach the Low level ②, then float switch start to work and the motorised valve ③ is opened by electric signal and condensed water is discharged.
    closeCondensed water is discharged through the motorised valve ③ and the water level get lower.
    Even though the float switch ② reach the original position, the valve is still opened during sometimes
    as per set-up inside and will be closed after set-up times.
    (Set-up times will vary for model and all have no loss of compressed air.)

    FLOAT Sensor

    Double float sensor improve the reliability. Especially compressor oil make a goodsensor.

    No Loss of Compressed Air

    Built-in Off Delay Timer make no loss of compressed air and the timer is set already in releasig and adjustable anytime.

    Automatic Discharge Function in case of emergency

    If the condensed water cannot be discharged, the alarm is activated (counter & alarm lamp flashed) by double float sensor and water is discharged all by the opening valve signal, then all the system return automatically. (If the above situation is repeated continually, the sytem need check)

    Visible Discharging Status

    You can see the level of condensed water by transparency FRP TUBE and can check the working status by manual handle of eletric valve. Push the button and turn the handle, manual operation can be avalable

    Check Discharging Capacity of Condensed Water (Check Working Times)

    Accumulated working times are showed on a counter in Display panel

    DISPLAY PANEL FUNCTION

    1) POWER : Show the power on
    2) VALVE : Show the valve working
    3) ALARM : Show the trap is working abnormally as water reach float high level(4) (Need check).
    4) COUNTER : Show the total working times of trap.
    The counting less than 100 times is caused by test before release
    5) TEST : Push "TEST" button, the valve is opened regardless of condensed water.
    6) RS-485 communication is available (OPTION)
    7) COUNTER In case of electric valve working : Show the valve opening time on second unit.(setting)

     SPECIFICATIONSDIMENSION
    WRET-1500WRET-3000MeasureWRET-1500WRET-3000
    Working Temperature2 ~ 70A158210
    Working Pressure0 ~ 12.0kgf/㎠B241299
    Power95~230V 1PH 60HzC177228
    Unit Capacity0.652.2LiterD138192
    Maximum Capacity4001000Liter/hrE94100
    AIR COMP.15005000HPFΦ11Φ9
    INLETPT1/2" Up & DownPT3/4" Up & Down2 point
    OUTLETPT 1/2"Electric Ball Valve
    OPTIONHEATER, RS485 Communication

    ** The reasonable capacity is one time working per 5~15 minutes.

    Installation 1

    1. Connect inlet and outlet of condensed water pipe
    2. Connect the balance line as the picture. [The pipe of balance line should be over 15A]
    3. Connecting should be separate for repairing.
    4. Connect the power (be sure the power is on)
    5. Installation1] is the best connection.
    6. Caution : Do not join the balance line to the middle of condensed water inlet line.

    Installation 2

    1. Connect inlet and outlet of condensed water pipe
    2. If the balance line is not connected, open he Speed Control v/v very slightly
    3. Connect the power (be sure the power is on)
    4. There is a loss of air in the case of Installation 2)

    Installation 3

    1. If the condensed water outlet is higher than the trap, use the balance line hole with the condensed water inlet.
    2. Stop up the inet at the bottom with plug or valve.
    3. Connect the power (be sure the power is on)
    4. Check the condensed water is flowed in.
    5. Discharge the early condensed water manually.
    ** NOTICE
    1. Be sure the compressed air is shut before installation.
    2. Check the leakage of trap and pipe after installation.
    3. Check the inflow to the trap.
    4. Push test button and check how it works
    5. Connecting should be separate for trap repairing.