The removal of condensed water under the compressed air system is absolute. If it isn't discharged, then the condensed water carrying over cooling type dryer or after cooler can damage seriously to the next processing equipments.

Kind of Trap

Air Loss

Loss Power

N㎥/min

Kwh

1/2" Manual Valve(1/2 open)

2.6

17.3

Disc/steam trap

0.11

0.76

Electric trap as per the time

 0.06

0.41

WRDT-SERIES

Disregard

Disregard

The above is presumed based on the working pressure 7 kgf/㎠ and it is flexible as per the installation condition,working time and etc. For more exact calculation to your conditions, please contact us.

Manual Ball Valve

You can lose the expensive compressed air as the valve leave opening to discharge the condensed water. and it make the system pressure lower and then obstruct the working of equipments.

General Mechanical float type

The oil and substance of condensed water may clog orifice which control open/close of trap and may make a small float not to work, so trap is opened. Then you should pay more expense by loss of compressed air.

Electric Trap by Sensor

The stain of sensor by oil and substance can be the reason of malfunction and the circuit board can be damaged by condensation. In case of malfunction, the self-repair is not easy.

Electric Trap by Timer

This is suitable for the place where the small condensed water come out, but too much exhaustion of compressed air may happen and it need to control the working time as per the using condition.

Steam Trap

For steam only.For both of normal working and without condensed water, the loss of compressed air can be continue.